Technical Data E 3000
Dimensions (L x W x H) in (mm) 181 x 91 x 94 (4600 x 2300 x 2400)
Ground clearance in (mm) 12 (305)
Weight (without fuel and no genset) lbs (kg) 5580 (2531)
Weight (with full fuel tank and genset) lbs (kg) 7715 (3499)
Fuel tank capacity gal (l) 230 (871)
Heat Transfer Fluid (HTF) tank capacity gal (l) 115 (435)
Pump gph (l/hr) 2 x 265 (2 x 1003)
Hose length ft (m) 3000 (914)
Hose reels 2
Hose rewind 120V AC, w/ 12V DC clutch
Circulation loops 2
Hitch 2-5?16” ball
Performance
Heater input (Gross) Btu/hr (kW) 385,000 (113)
Heater output (Net) Btu/hr (kW) 321,000 (94)
Heater efficiency % 83
Temperature controller digital
Fuel consumption at full load (without genset) gph (l/hr) 2.75 (10.4)
Fuel consumption at full load (with genset) gph (l/hr) 3.17 (12)
Fuel requirement winter blend diesel
Run time hr up to 140
Electrical 115V, 2 x 20 amps
Normal operating temp °F 100 - 180
Normal hose operating pressure psi (kPa) 110 (758)
HTF flow rate per loop gal/hr 265
Thawing capacity (standard / with accessories) ft² (m²) 3000 - 6000 (279 - 557) / up to 6000 (557)
Curing capacity (standard / with accessories) ft² (m²) up to 6000 (557) / up to 18000 (1672)
Frost prevention (standard / with accessories) ft² (m²) up to 9000 (836) / up to 27,000 (2508)
Air heat capacity (with accessories) ft³ (m³) 525,000 (14,866)
Performance monitoring light yes